On the Road 7 Days a WeekGas Safe Reg.597490 • CSCS Members • DBS Enhanced • Est.2017
📞 0115 905 1208
Merlin gas safety system interlock panel installed by Castle Catering Engineers
CT1650+ gas safety system panel live with fan and gas status indicators lit
Home/Services/Gas Interlocking Systems

Gas Interlocking
Systems

Design, installation and CP42 certification of commercial kitchen gas interlocking systems. Gas Safe Licence 597490. Merlin CT1650+ and 3000S. 3-year guarantee on all installations.

Gas Safe Licence 597490
Legal Requirement BS6173
CP42 Certification
Merlin CT1650+ & 3000S
3-Year Guarantee
CO & CO₂ Monitoring
DBS Enhanced Approved
East Midlands Based
Gas Interlocking Systems

Legally Required. CP42 Certified.
3-Year Guarantee.

A gas interlocking system links your gas supply to your ventilation system. It is a legal requirement under BS6173 in all commercial kitchens. When ventilation fails, the interlock cuts the gas supply — preventing CO build-up and the risk of explosion. Operating without a correctly installed and certified system can invalidate your insurance and risk EHO closure.

Castle Catering Engineers installs gas interlocking systems across Nottinghamshire and the East Midlands. All work is carried out by Gas Safe registered engineers (Licence 597490) with a CP42 Commercial Gas Safety Certificate and 3-year guarantee on every installation.

Free Compliance Check Available

Call 0115 905 1208 for a free gas interlock compliance check across Nottinghamshire and the East Midlands.

Systems we install

  • Merlin CT1650+ — fan current monitoring, CO and CO₂ sensors
  • Merlin 3000S — variable speed ventilation, multi-sensor integration
  • Emergency stop buttons and manual override devices
  • Gas solenoid valve installation and commissioning
  • Interlock panel wiring and calibration
  • CP42 Commercial Gas Safety Certificate on completion
  • 3-year guarantee on all parts and labour
🔬
Merlin CT1650+
Fan current monitoring, CO and CO₂ sensors, accurate calibration for maximum kitchen safety.
🔬
Merlin 3000S
Variable speed ventilation — gas usage, CO₂, smoke/steam and heat detection. Single compact panel.
📋
CP42 — Gas Safe 597490
Full CP42 Commercial Gas Safety Certificate issued by Gas Safe engineers (Licence 597490) on every installation.
🛡️
3-Year Guarantee
All gas interlocking systems carry a full 3-year parts and labour guarantee.
Accreditations & Qualifications
🔥
Gas Safe
Licence 597490
🏗️
CSCS
Members
DBS Enhanced
Approved
Our Own Control Panel

The CCE Merlin Gas Interlock & Safety System

Every gas kitchen we install includes a gas interlocking system — a legal requirement under BS6173. Our own Merlin CT1250 control panel is fitted on every gas kitchen we install.

CCE Merlin CT1250 gas interlock and safety system control panel with emergency shut-off, fan monitoring and gas isolation, manufactured by Castle Catering Engineers

The Merlin panel links the extraction and supply fans directly to the gas supply. If ventilation drops below the required rate, the system automatically isolates the gas — keeping the kitchen safe and compliant at all times.

  • Emergency gas shut-off
  • Extract & supply fan monitoring
  • Automatic gas isolation on ventilation failure
  • Fan-fault and service indication
The Merlin Range

Gas Interlock Panels & Detectors We Install

We supply, install, commission and service the full Merlin range from S&S Northern — from single-fan kitchens through to multi-fan installations with CO, CO₂ and temperature monitoring. Every installation is carried out by Gas Safe registered engineers (Licence 597490) and CP42 certified on completion.

Merlin CT1250 Gas Safety System — supplied and installed by Castle Catering Engineers, Gas Safe Licence 597490
CT1250
Merlin CT1250 Gas Safety System

The entry-level panel in the Merlin range and the one we fit as standard on most gas kitchens. It links the supply and extract fans to the gas supply and isolates the gas automatically if ventilation fails.

  • Power, Gas On and EM Stop indication
  • Supply fan and extract fan monitoring
  • Fan fault and service indication
  • Emergency shut-off and mute
Merlin CT1650+ Gas Safety System — supplied and installed by Castle Catering Engineers, Gas Safe Licence 597490
CT1650+
Merlin CT1650+ Gas Safety System

A step up from the CT1250, adding CO₂ monitoring and dual-fan supervision. Suited to larger kitchens, or any site where air quality needs monitoring alongside the interlock.

  • Power, Gas On and EM Stop indication
  • Fan 1 OK and Fan 2 OK monitoring
  • CO₂ High warning
  • Fan fault indication, emergency shut-off and mute
Merlin CT1750 Kitchen Safety System — supplied and installed by Castle Catering Engineers, Gas Safe Licence 597490
CT1750
Merlin CT1750 Kitchen Safety System

A full kitchen safety system rather than an interlock alone. Alongside gas control it takes inputs from CO, CO₂ and temperature sensors and the fire panel, and includes built-in speed control for two fans.

  • Integrated fan speed control for two fans
  • CO, CO₂ and temperature sensor inputs
  • Fire panel interface
  • Testing, test fail and low pressure indication
Merlin 2000X Gas Safety System — supplied and installed by Castle Catering Engineers, Gas Safe Licence 597490
2000X
Merlin 2000X Gas Safety System

The largest panel in the range, built for multi-fan installations. It supervises banks of supply and extract fans together and adds automatic self-testing.

  • Supply fans and extract fans supervision
  • Automatic testing with test fail indication
  • Gas detected, CO₂ high and fire alarm inputs
  • Pressure low and time-out indication
Merlin Gas Detector i — supplied and installed by Castle Catering Engineers, Gas Safe Licence 597490
DETECTOR i
Merlin Gas Detector i

A wall-mounted gas detector that works alongside the interlock panel. Simple LED indication of low and high gas levels, with a warning when the sensor reaches the end of its service life.

  • Low and high gas level indication
  • Sensor life exceeded warning
  • Wall-mounted, links to the Merlin panel
Merlin Gas Detector i-S — supplied and installed by Castle Catering Engineers, Gas Safe Licence 597490
DETECTOR i-S
Merlin Gas Detector i-S

The digital version of the Detector i, with a live ppm readout on a colour display. Gives a pre-alarm before the full alarm stage and provides a 0–10V output for building management systems.

  • Live ppm reading on colour display
  • Pre-alarm and alarm stages
  • 0–10V output for BMS integration
  • Available for CO and other gases
Merlin CO₂ X Monitor — supplied and installed by Castle Catering Engineers, Gas Safe Licence 597490
CO₂ X
Merlin CO₂ X Monitor

A CO₂ monitor with a full display showing current and average CO₂ levels alongside room temperature. Commonly specified where ventilation performance needs to be demonstrated as well as controlled.

  • Live and average CO₂ readings in ppm
  • Room temperature display
  • Visual level indication
  • Links to the Merlin control panel
FAQs

Common Questions

Yes. Under BS6173 and Gas Safe regulations, a gas interlock is required in all new commercial kitchens. Castle Catering Engineers (Gas Safe Licence 597490) install and certify systems across the East Midlands, issuing CP42 on completion.

All gas interlocking systems carry a 3-year parts and labour guarantee.

Yes. All engineers are Gas Safe registered (Licence 597490), CSCS members and DBS Enhanced approved — cleared for education sites without delay.

A standard installation typically takes one day. Complex systems may take two. We can schedule work outside kitchen hours to minimise disruption.

📞
Phone
📍
Address
Unit 8 Pottery Court, Pottery Way, Bulwell, Nottingham, NG6 8YN
🕐
Hours
Mon–Fri 07:00–17:00 • Sat–Sun On-Call 08:00–17:00 • Emergency Out of Hours: Leave a Voicemail
Send an Enquiry
We aim to respond within 24–48 hours.

Sent directly to info@ccecatering.com • Your details are kept confidential

Enquiry sent — thank you! We aim to respond within 24–48 hours. Urgent? Call 0115 905 1208.
Something went wrong. Email info@ccecatering.com or call 0115 905 1208.

Is Your Kitchen Gas-Interlock Compliant?

Gas Safe Licence 597490 — free compliance check available. We install, certify and guarantee all systems across the East Midlands.

Gas Safe 597490CP42 Certified3-Year GuaranteeDBS EnhancedFree Compliance Check

We’d like to use analytics cookies to understand how visitors use this site so we can improve it. These are only set if you accept. Declining will not affect how the site works.